Journal of Inorganic Materials

• Research Paper • Previous Articles     Next Articles

Residual Stress and Bond Strength of Bioactive Gradient Coatings Plasma-sprayed

WANG Ying-Jun; NING Cheng-Yun; CHEN Kai; ZHAO Zi-Zhong; LI Shang-Zhou; MA Li-Tai+; FENG Jing-Wei+; HUANG Rui-Fu+   

  1. South China University of Technology Guangzhou 510641 China; +Shanghai Institute of Ceramics; Chinese Academy of Sciences Shanghai 200050 China
  • Received:1997-10-05 Revised:1998-01-19 Published:1998-08-10 Online:1998-08-10

Abstract: A material of bioactive gradient coatings was designed. The difference of thermal expansion coefficients between coating and substrate was reduced. The residual stress within the plasmasprayed coatings heat-treated was reduced. The bonding strength of the coatings was measured to be about 38 MPa. The residual stress produced within the coatings was measured by the sin2Ψmethod of XRD, and the influence of residual stress on the bond strength of the coatings was explored.

Key words: bioactive gradient coating, plasma-spray, residual stress, bonding strength